Pilot assisted overcentre valve, cartridge type

mod. OVC200-C


Maximum flow 200 l/min
Maximum pressure 350 bar
Standard pilot ratio 4:1
Pilot ratio upon request 3:1 8:1
Tightening torque 240÷260 Nm
Setting The valve must be set at least 1.3 times maximum load induced pressure
Code Standard setting
bar (Q= 5l/min)
Setting range
bar
Spring color
01 100 20÷200 White
02 280 50÷350 Black
Options
-
reg_A.jpg
Leakproof hex socket screw
C
OVC150_REG_C.jpg
Sealing cap 
D
OVC150_REG_D.jpg 
Cap

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm

Ordering examples: OVC200C02

Click to enlarge
code description
(Ordering code)
Max flow
l/min gpm
Max pressure
bar psi
cavity
OVC00480 OVC200C01 200 52.8 350 5075 CAV00051
OVC00481 OVC200C02 200 52.8 350 5075 CAV00051
OVC00484 OVC200C01 R.P.3:1 200 52.8 350 5075 CAV00051
OVC00485 OVC200C02 R.P.3:1 200 52.8 350 5075 CAV00051
OVC00486 OVC200C01 R.P.8:1 200 52.8 350 5075 CAV00051
OVC00487 OVC200C02 R.P.8:1 200 52.8 350 5075 CAV00051
<< 7 / 16 in CARTRIDGE >>