Italiano English
e-mail  pswd  Log In  Create an Account 

Pilot assisted overcentre valve, cartridge type

mod. OVC4010-C


Maximum flow 20 l/min
Maximum pressure 350 bar
Standard pilot ratio 4:1
Tightening torque 30÷35 Nm
Setting The valve must be set at least 1.3 times maximum load induced pressure
Code Standard setting
bar (Q= 5l/min)
Setting range
bar
Spring color
01 100 20÷200 White
02 280 50÷350 Black

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm

Ordering examples: OVC2008C02

Click to enlarge
code description
(Ordering code)
Max flow
l/min gpm
Max pressure
bar psi
cavity
OVC00537 OVC4010C02 40 10.6 350 5075 CAV00040
OVC00544 OVC4010C01 40 10.6 350 5075 CAV00040
<< 2 / 16 in CARTRIDGE >>