Pilot assisted overcentre valve, cartridge type

mod. OVC4010CC-C


Maximum flow 40 l/min
Maximum pressure 350 bar
Standard pilot ratio 4:1
Tightening torque 50÷60 Nm
Setting The valve must be set at least 1.3 times maximum load induced pressure
Code Standard setting
bar (Q= 5l/min)
Setting range
bar
Spring color
01 100 20÷200 White
02 280 50÷350 Black

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm

Ordering examples: OVC4010CCC02

Click to enlarge
code description
(Ordering code)
Max flow
l/min gpm
Max pressure
bar psi
cavity
OVC00538 OVC4010CCC02 40 10.6 350 5075 CAV00040
OVC00546 OVC4010CCC01 40 10.6 350 5075 CAV00040