Pressure compensated, pilot assisted overcentre valve, cartridge type

mod. OVC2008CC-C


Maximum flow 20 l/min
Maximum pressure 350 bar
Standard pilot ratio 4:1
Tightening torque 30÷35 Nm
Setting The valve must be set at least 1.3 times maximum load induced pressure
Code Standard setting
bar (Q= 5l/min)
Setting range
bar
Spring color
01 100 20÷200 White
02 280 50÷350 Black

Performaces and calibrations are carried out by using hydraulic oil with 30 cSt viscosity at 50°C
Recommended viscosity 10 ÷ 420 cSt
Working temperature -20 ÷ +90 °C
Absolute filitration 25 μm

Ordering examples: OVC2008CCC02

Click to enlarge
code description
(Ordering code)
Max flow
l/min gpm
Max pressure
bar psi
cavity
OVC00540 OVC2008CCC02 20 5.3 350 5075 CAV00037
OVC00545 OVC2008CCC01 20 5.3 350 5075 CAV00037